A dedicated system for checking and refilling nitrogen in hydraulic accumulators, always ensuring the correct preloading pressure

The Nitrogen Booster is used to load accumulators — individually or within an HPU — with nitrogen at the correct preloading pressure, transferring gas from the cylinder to the accumulator down to a minimum pressure of 20 bar in the cylinder itself.

The nitrogen preloading pressure of bag and piston accumulators must be checked periodically (approximately every 3-6 months) and, if necessary, corrected to the required value.

These checking and refilling operations must be carried out without back-pressure on the oil side: for this reason, before working on the accumulator, the oil side must be disabled and drained using the manual cut-off and decompression valve.

The Nitrogen Booster is connected to the electrical system and to the nitrogen cylinder via the "IN PB" coupling, and to the accumulator to be refilled via a hose connected to the "OUT ACC" coupling.

It is also available in the Ex Model (ATEX) version, for use in explosive atmospheres.

TALK TO AN EXPERT

Contact a specialist

Division:

Nitrogen booster

Competence:

Sales / Technical

Do you need to check or restore the preloading pressure of your accumulators? Contact us.

go

Technical data

Technical data

Tank capacity:

40 L

Type of fluid:

HLP

Oil viscosity:

46 cSt at 40°

Capacity:

4,9 lt/min

Max Pressure:

220 bar (3200 psi)
440 bar version available (on request)

Electric motor:

2,2kW 400V/50Hz 
Available Explosion proof - CLASS I DIVISION II -ATEX

Temperature range:

-15°C to +60°C (Room temperature)

Technical specifications

Dimensions (mm):

1350 (H)x990 (D)x560 (W)

Weight:

180 kg (without oil)

Materials:

S275JR